THE SINGLE BEST STRATEGY TO USE FOR DP50RB

The Single Best Strategy To Use For Dp50rb

The Single Best Strategy To Use For Dp50rb

Blog Article

Guidance 4D probe; identify the probe via the ID code; swap the 4D drive sign by using the  electrical relay to create the 4D probe perform Generally. 4.2.2 Principal board The primary board may be divided into two areas: front-conclusion of the main board and back-conclusion of the main board.

1.two.2 Warning Labels Warning Labels Meaning Please carefully read through this manual before use machine. The next labels certainly are a. Do not position the unit over a sloped surface area. Otherwise the readily available once the procedure unit may slide, leading to own injuries or maybe the unit is effective With all the cell malfunction.

Evaluating individuals in nowadays’s demanding environment demands progressive technological know-how that permits clinicians to create swift and assured diagnoses. The versatility on the DP-50 expands your scientific utility while helping to strengthen patient treatment.

The consumer is just not permitted to open up the handles and panel of the method, neither Notice: system disassemble is permitted. To ensure the program effectiveness and basic safety, only Mindray engineers or engineers approved by Mindray can conduct upkeep.

By continuing your pay a visit to on our Site, you might be consenting to our usage of cookies. On the other hand, you can change your cookie configurations at any time.  Cookie desire Take and Move forward

Site 145 Clean up control panel Resources: dry smooth cloth, gentle soapy water  System:  Use dry delicate cloth to scrub the area in the system. Should the technique is soiled, moisten the smooth cloth with delicate soapy water and wipe off any stains. Use dry comfortable fabric to get rid of any moisture and permit all tricky surfaces to entirely air-dry. Site 146: Clean The Peripherals

Critical details about our connection along with you: Customer Connection Summaries Our Customer Partnership Summaries provide a brief summary of our companies, costs and obligations after we get the job done along with you inside a broker-vendor or an expense advisory marriage.

S. will have to deliver the Division having an e mail deal with if they may have one. The e-mail delivered can be utilized for Formal communication While using the licensee. However e mail addresses are community record. If you do not want to provide a personal deal with, remember to supply the Section with an electronic mail address that may be created available to the public. To determine In case you are a licensee below Chapter 455, File.S., make sure you Just click here . Product Acceptance Accepts:

Perform: On the back-stop of the principle board, a Distinctive check IC is used to observe signal voltages  and clock battery energy which might be presented to the leading board by the leading device box electrical power source module.

Right after successful relationship, the newly included network printer name are going to be shown in the printer driver record. Observe: In advance of link the network printer, make certain the ultrasound system and the printer are in the exact same network domain, and the network is Doing the job Commonly. The IP address and the server identify should be valid, e.g. Website page forty seven DICOM Placing  Enter the AE Title in the ultrasound method, port and PDU based on the actual problem, and afterwards click [Okay] to exit the display screen.

Page forty five Return “Printer Provider” website page, Pick the corresponding support in the printer list and increase the company. The procedure integrates motorists of HP printers, soon after HP printers are related, drivers will be set up quickly (about 10s).If auto installation fails, icon will Show on the best decrease corner on the screen to alert you that manual installation is essential. Webpage 46: Community Preset

Most 4 occasions tasking for a person transmitted beam, leading to great time resolution and higher frame amount.

Soon after replacing the CPU module, crucial file have to be created Again according to the new MAC tackle and prepared into HDD of the device. Or else, the configuration function with the product is going to be shed. Immediately after eliminating the CPU module, Take out panhead screws with washers (12 M3X6) fixed on the main device box, you may take from the board. Webpage 118 Determine 8-29 Disassemble the User interface Assembly (one) Hold the higher edge of user interface assembly, and open up up the user interface. Determine eight-30 Disassemble the User interface Assembly (two) Just after removing 1 countersunk head self-tapping screw PT3X10 set within the control panel and consider out the plug from the keyboard and the key unit connecting cables, you can eliminate the user interface assembly.

Functionality Check five.five.1 Exam Approach Resolution Detection depth Geometric Situation Precision Blackout spot test Record the exam images 5.5.2 Take a look at Written content The picture made use of here is just for reference, stick to the graphic impact in the actual Be aware: predicament. Specifications: Show: established the contrast and brightness at the medical application value (or the default status) Operation atmosphere: dark room, simulating the medical application surroundings. Site seventy six In affliction that the transverse resolution testing targets are horizontally shown, report the small length of two targets which can be Obviously acknowledged. Repeat the Procedure above with the transverse resolution screening targets at other depths. As revealed in figure underneath. Axial resolution ... Web page 77 When utilizing the convex probe, hold the transverse resolution tests targets to NOTE: be displayed close to the midline. When employing a linear probe with steer function, will not turn on the steer operate when perform the transverse Dp50rb login resolution examination. Zoom during the region wherever the targets Situated if important. The diameter of the goal place at a specific depth is equal to the transverse resolution within the depth. Site 78 5.

A smart new condition, enhanced mobility and convenient Procedure make DP-fifty well suited for all scientific settings.

5.2.3 Geometric positioning accuracy Longitudinal geometric positioning accuracy  Check Stage: Do adjustments as the way in testing the maximum depth. File the gap by 20mm Just about every section to the longitudinal targets line utilizing the measurement caliper; Decide on the value with the greatest mistake (to 20mm), work out the precision using the formulation beneath The measurement caliper needs to be positioned on the upper edge of the goal, Observe:... Page seventy nine Transverse geometric positioning accuracy  Take a look at Action: Deal with the scan floor on the phantom with water or couple gel, Carefully Get in touch with the probe Together with the scan surface Regulate the depth, making the transverse targets to get displayed during the image. Regulate the main focus point to generally be posited beside the transverse targets (the common just isn't clear) Alter parameters like acquire, TGC, earning Every single transverse targets to become Plainly exhibited. Webpage eighty five.5.2.4 Blackout Space Examination Stage: Protect the scan surface on the phantom with drinking water or few gel, gently contact the probe With all the scan surface Change the depth in a decreased benefit, and set the focus at the nearest spot to the scan floor. Lower the worth of parameters like AP, Attain right until the background noise just is often found. Page 81: Computer software Up grade And Servicing

Report this page